Fix LoRaWAN PHY settings for SX126x driver

* Set preamble length to 8 symbols
* Set polarity to inverted for received messages
This commit is contained in:
Justin Beaurivage 2022-11-20 16:08:43 -05:00
parent 2528f45138
commit 81dc532d2d

View File

@ -87,7 +87,7 @@ where
config.rf.spreading_factor.into(), config.rf.spreading_factor.into(),
config.rf.bandwidth.into(), config.rf.bandwidth.into(),
config.rf.coding_rate.into(), config.rf.coding_rate.into(),
4, 8,
false, false,
true, true,
false, false,
@ -119,14 +119,14 @@ where
config.spreading_factor.into(), config.spreading_factor.into(),
config.bandwidth.into(), config.bandwidth.into(),
config.coding_rate.into(), config.coding_rate.into(),
4, 8,
4, 4,
false, false,
0u8, 0u8,
true, true,
false, false,
0, 0,
false, true,
true, true,
) )
.await?; .await?;