1024: stm32/adc: Remove voltage and temperature conversions r=Dirbaio a=GrantM11235
The current conversion utilities are confusing and a bit of a footgun. (Two out of the three examples got it wrong! They didn't measure vref at all, so all the conversions are completely wrong if vcca isn't 3.3v)
I think we should eventually have some sort of conversion utilities in the HAL, but for now I think it is best to just remove it and let the users do their own math.
cc `@chemicstry`
Co-authored-by: Grant Miller <GrantM11235@gmail.com>
It was only useful for doing #[embassy_executor::main(config = "config()")]`. Now that
it's gone, it makes more sense to build the config in main directly.
- Remove unused `MilliSeconds`, `MicroSeconds`, and `NanoSeconds` types
- Remove `Bps`, `KiloHertz`, and `MegaHertz` types that were only used
for converting to `Hertz`
- Replace all instances of `impl Into<Hertz>` with `Hertz`
- Add `hz`, `khz`, and `mhz` methods to `Hertz`, as well as
free function shortcuts
- Remove `U32Ext` extension trait
SMI Ethernet PHYs all share a common base set of registers that can do
90% of all tasks. The LAN8742 driver used some vendor-specific
registers to check link negotiation status, but the need for that was
debatable, so I migrated it to a generic driver instead, anybody who
wants extra functionality can copy it and impl their own on top of it.